Getting Started Manual WaveSurfer® MXs-B Oscilloscopes
WaveSurfer MXs-B Oscilloscopes 2 922172-00 Rev A Safety Instructions This section contains instructions that must be observed to keep the instrument
WaveSurfer MXs-B Oscilloscopes 92 922172-00 Rev A Aux Output The following signals can be output through the AUX OUTPUT coaxial connector on the back
Getting Started Manual 922172-00 Rev A 93 Setting the Date and Time The instrument gives you the choice of manually setting the time and date or get
WaveSurfer MXs-B Oscilloscopes 94 922172-00 Rev A Options Use this dialog to add or remove software options. For information about software options,
Getting Started Manual 922172-00 Rev A 95 for this procedure. Using your finger provides insufficient accuracy. The calibration has a ten-second tim
WaveSurfer MXs-B Oscilloscopes 96 922172-00 Rev A Local Language The WaveSurfer MXs-B oscilloscope can be configured to display a user interface in d
Getting Started Manual 922172-00 Rev A 97 If you chose MAPI, touch inside the Originator Address (From:) data entry field and use the pop-up keyboar
WaveSurfer MXs-B Oscilloscopes 98 922172-00 Rev A Standards Teledyne LeCroy remote control commands conform to the GPIB IEEE 488.21 standard. This
Getting Started Manual 922172-00 Rev A 99 It is important to note that Automation itself is not software language dependent. Meaning, it can be used
WaveSurfer MXs-B Oscilloscopes 100 922172-00 Rev A Software Recovery Application Your oscilloscope is designed to operate reliably for many years. Ho
Getting Started Manual 922172-00 Rev A 101 NOTE: If you minimize the application, touch the appropriate task bar or desktop icon to maximize it:
Getting Started Manual 922172-00 Rev A 3 Observe all terminal ratings. Do not apply a voltage to any input (C1, C2, C3, C4 or EXT) that exceeds t
WaveSurfer MXs-B Oscilloscopes 102 922172-00 Rev A Reference Certifications This section contains the instrument’s Electromagnetic Compatibility (EMC
Getting Started Manual 922172-00 Rev A 103 2 Emissions which exceed the levels required by this standard may occur when the oscilloscope is connecte
WaveSurfer MXs-B Oscilloscopes 104 922172-00 Rev A EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laborat
Getting Started Manual 922172-00 Rev A 105 Environmental Compliance END-OF-LIFE HANDLING The instrument is marked with this symbol to indicate that
WaveSurfer MXs-B Oscilloscopes 106 922172-00 Rev A Contact Teledyne LeCroy Teledyne LeCroy Service Centers United States and Canada - World Wide Cor
Getting Started Manual 922172-00 Rev A 107 X-Stream Software End-User License Agreement IMPORTANT-READ CAREFULLY: THIS END-USER LICENSE AGREEMENT (&
WaveSurfer MXs-B Oscilloscopes 108 922172-00 Rev A prepare derivative works (“Derivatives”) of the source code version of those portions of the Softw
Getting Started Manual 922172-00 Rev A 109 functionality similar to or competitive with the Software Product; (e) publish benchmark results relating
WaveSurfer MXs-B Oscilloscopes 110 922172-00 Rev A commercially available. The License with respect to the Prerelease Code terminates upon availabili
Getting Started Manual 922172-00 Rev A 111 Confidential Information, including ensuring that its employees and consultants with access to such Confi
WaveSurfer MXs-B Oscilloscopes 4 922172-00 Rev A beneath the oscilloscope clear of paper and other items. The instrument also has internal fan contro
WaveSurfer MXs-B Oscilloscopes 112 922172-00 Rev A a third party without restriction on subsequent disclosure, or (e) independently developed by the
Getting Started Manual 922172-00 Rev A 113 production of nuclear, chemical or biological weapons; or (c) to any end-user who has been prohibited fro
WaveSurfer MXs-B Oscilloscopes 114 922172-00 Rev A MAY NOT APPLY TO YOU. THESE LIMITATIONS ARE INDEPENDENT FROM ALL OTHER PROVISIONS OF THIS EULA AN
Getting Started Manual 922172-00 Rev A 115 8.5. Assignment. This EULA and the rights and obligations hereunder, may not be assigned, in whole or in
WaveSurfer MXs-B Oscilloscopes 116 922172-00 Rev A
Getting Started Manual 922172-00 Rev A 5 Standby Power The Power (Standby) button controls the operational state of the oscilloscope. Press the b
WaveSurfer MXs-B Oscilloscopes 6 922172-00 Rev A Software Find out the oscilloscope's software and hardware configuration by choosing Utilities
Getting Started Manual 922172-00 Rev A 7 Basic Controls Front Panel The WaveSurfer MXs-B front panel is designed to allow you to operate basic oscil
WaveSurfer MXs-B Oscilloscopes 8 922172-00 Rev A Vertical Controls Vertical Controls are multiplexed for each channel. The lighted channel button in
Getting Started Manual 922172-00 Rev A 9 Horizontal Controls Set up the timebase by using the front panel Horizontal controls, just as for analog o
WaveSurfer MXs-B Oscilloscopes 10 922172-00 Rev A AutoSetup Button Automatically sets timebase, trigger, and sensitivity to display a wide range of
Getting Started Manual 922172-00 Rev A 11 Adjust Knob The adjust knob can be used to make adjustments to a value when a dialog is open and the sele
WaveSurfer MXs-B Oscilloscopes 12 922172-00 Rev A Probe and Signal Connection Interfaces Teledyne LeCroy WaveSurfer MXs-B oscilloscopes contain probe
Getting Started Manual 922172-00 Rev A 13 Passive Probe Compensation Passive probes must be compensated to flatten overshoot. This is accomplished b
WaveSurfer MXs-B Oscilloscopes 14 922172-00 Rev A Menu Bar The top menu bar provides access to various software dialogs. It is very similar to the Fi
Getting Started Manual 922172-00 Rev A 15 Grid Area The grid area is divided into 8 vertical divisions and 10 horizontal divisions. There are sever
WaveSurfer MXs-B Oscilloscopes 16 922172-00 Rev A Post-trigger delay is indicated by a color-coded arrow pointing to the left. All trigger delay
Getting Started Manual 922172-00 Rev A 17 Descriptor Labels Information is contained in rectangular boxes called descriptor labels. These labels con
WaveSurfer MXs-B Oscilloscopes 18 922172-00 Rev A Touch the timebase descriptor label once to open the software dialog for further adjustment. The t
Getting Started Manual 922172-00 Rev A 19 Mouse and Keyboard Operation In the procedures, we focus on using the front panel for common operations, a
WaveSurfer MXs-B Oscilloscopes 20 922172-00 Rev A At this point, the following dialog is shown at the bottom of the display, and the grid area shorte
Getting Started Manual 922172-00 Rev A 21 Bandwidth Limiting You may sometimes want to limit high frequency noise on a very low bandwidth input sign
WaveSurfer® MXs-B Series Oscilloscopes Getting Started Manual January, 2013
WaveSurfer MXs-B Oscilloscopes 22 922172-00 Rev A Opens a Measurement selection pop-up menu. You can then select up to 6 parameters (measurements) f
Getting Started Manual 922172-00 Rev A 23 Sampling Modes Depending on your timebase, the following sampling modes are available: WaveStream Mode -
WaveSurfer MXs-B Oscilloscopes 24 922172-00 Rev A event, while post-trigger delay is the time back to the event. You can sample the waveform in a ran
Getting Started Manual 922172-00 Rev A 25 You can combine sequence mode with an advanced trigger to isolate a rare event, capture all instances o
WaveSurfer MXs-B Oscilloscopes 26 922172-00 Rev A RIS Sampling Mode - For Higher Sampling Rates RIS (Random Interleaved Sampling) is an acquisition t
Getting Started Manual 922172-00 Rev A 27 WaveStream Fast Viewing Mode / Intensity WaveStream fast viewing mode provides brightness-graded intensit
WaveSurfer MXs-B Oscilloscopes 28 922172-00 Rev A Triggering Overview The oscilloscope uses many waveform capture techniques that trigger on features
Getting Started Manual 922172-00 Rev A 29 Level – the threshold at which the trigger will occur, specified in volts. Slope – the direction of
WaveSurfer MXs-B Oscilloscopes 30 922172-00 Rev A Trigger Level Indicator The trigger level indicator is a color-coded triangle that is positioned v
Getting Started Manual 922172-00 Rev A 31 2. Touch inside the Source field in the Setup section and select an input from the pop-up menu: C1 th
700 Chestnut Ridge Road Chestnut Ridge, NY, 10977-6499 Tel: (845) 425-2000 Fax: (845) 578 5985 teledynelecroy.com © 2013 Teledyne LeCroy, Inc. All
WaveSurfer MXs-B Oscilloscopes 32 922172-00 Rev A 5. Select a trigger Slope from the Slope section: Positive and Negative slope refers to the vol
Getting Started Manual 922172-00 Rev A 33 Basic Triggers Edge Use Edge trigger for simple, repetitive signals. This trigger is activated by basic w
WaveSurfer MXs-B Oscilloscopes 34 922172-00 Rev A SMART Triggers SMART Triggers are as follows: Glitch Glitch trigger is a simpler form of Width tr
Getting Started Manual 922172-00 Rev A 35 Serial Trigger and Decode (Optional) Optional WaveSurfer MXs-B capabilities support triggering and decodin
WaveSurfer MXs-B Oscilloscopes 36 922172-00 Rev A Serial Decode and Decode Setup These dialogs provide the ability to set the oscilloscope up for pro
Getting Started Manual 922172-00 Rev A 37 Viewing Waveforms Display Setup NOTE: Not all grid styles are available on all instruments. To set up yo
WaveSurfer MXs-B Oscilloscopes 38 922172-00 Rev A In all cases, the zoomed channels are displayed in a separate half-height grid at the bottom of the
Getting Started Manual 922172-00 Rev A 39 FRONT PANEL QUICKZOOM BUTTON Pressing the front panel QuickZoom button creates Zoom traces for all chan
WaveSurfer MXs-B Oscilloscopes 40 922172-00 Rev A Zoom Descriptor Label When a Zoom trace is ON, there is a descriptor label on the display for it, m
Getting Started Manual 922172-00 Rev A 41 Then, use the front panel horizontal and vertical controls to adjust position and scale. The operation of
Getting Started Manual 922172-00 Rev A i TABLE OF CONTENTS Welcome ...
WaveSurfer MXs-B Oscilloscopes 42 922172-00 Rev A Using Toolbar Shortcuts These toolbar shortcuts can be used to perform specific actions for each Zo
Getting Started Manual 922172-00 Rev A 43 Turning On Cursors Cursors automatically turn on when either knob is rotated. Or, you can press the TYPE b
WaveSurfer MXs-B Oscilloscopes 44 922172-00 Rev A Horizontal (Frequency) Horizontal (Frequency) cursors are moved left and right along the FFT Math t
Getting Started Manual 922172-00 Rev A 45 Reading Cursor Information Cursor information is displayed in two different places on the WaveSurfer MXs-B
WaveSurfer MXs-B Oscilloscopes 46 922172-00 Rev A Measuring with Parameters Overview Parameters are pre-programmed measurements that eliminate the ne
Getting Started Manual 922172-00 Rev A 47 2. The default status has parameters turned OFF, and all are undefined (None). Touch either the icon or
WaveSurfer MXs-B Oscilloscopes 48 922172-00 Rev A 4. The channel source defaults to C1. Touch inside the Source field to select a different source (
Getting Started Manual 922172-00 Rev A 49 The format is Px:Name(source) with value and status contained as follows: P1, P2, P3, P4, P5, P6 The num
WaveSurfer MXs-B Oscilloscopes 50 922172-00 Rev A Parameter Gates (Windows) Sometimes you might want a parameter measurement on a specific portion o
Getting Started Manual 922172-00 Rev A 51 Viewing Thumbnail Histograms Histicons are miniature histograms of parameter measurements that appear bel
WaveSurfer MXs-B Oscilloscope ii 922172-00 Rev A Descriptor Labels ...
WaveSurfer MXs-B Oscilloscopes 52 922172-00 Rev A Signal Views WaveScan provides distinct views of your signal: Source view highlights all occurr
Getting Started Manual 922172-00 Rev A 53 Parameter Measurements Besides parameter measurements made during acquisition, post-acquisition measuremen
WaveSurfer MXs-B Oscilloscopes 54 922172-00 Rev A Zoom View An individual edge can be zoomed by selecting it from the table of found events at the le
Getting Started Manual 922172-00 Rev A 55 Edge Mode This search mode locates all edges in an acquisition and presents them time-stamped in a table.
WaveSurfer MXs-B Oscilloscopes 56 922172-00 Rev A The hysteresis value is used to eliminate noise. A non-monotonicity is detected only when its ampl
Getting Started Manual 922172-00 Rev A 57 In the case of positive-going runt pulses, the value displayed in the table is the absolute value of the
WaveSurfer MXs-B Oscilloscopes 58 922172-00 Rev A Measurement Mode This search and scan mode lets you apply filters to your acquisitions to highlight
Getting Started Manual 922172-00 Rev A 59 SCAN FILTERS But, now we want to look at fall times greater than 45.5 ns; 3 falling edges from the same ac
WaveSurfer MXs-B Oscilloscopes 60 922172-00 Rev A FILTER METHODS While the Filter Wizard provides a quick way to apply filtering criteria automatica
Getting Started Manual 922172-00 Rev A 61 Working with Sampling Modes Sequence Mode Setup When setting up Sequence Mode, you define the number of fi
Getting Started Manual 922172-00 Rev A iii Cursor Types ... 43 R
WaveSurfer MXs-B Oscilloscopes 62 922172-00 Rev A 4. Touch the Enable Timeout checkbox. 5. Touch inside the Timeout data entry field and enter a ti
Getting Started Manual 922172-00 Rev A 63 OR If you want to zoom in or out in large standard increments with each touch of the zoom control buttons
WaveSurfer MXs-B Oscilloscopes 64 922172-00 Rev A Using the Math Trace Overview Math allows you to perform simple and complex mathematical calculatio
Getting Started Manual 922172-00 Rev A 65 Description of math functions The WaveSurfer MXs-B oscilloscope contains several Math operators as standa
WaveSurfer MXs-B Oscilloscopes 66 922172-00 Rev A Product (Multiply) – Multiplies two waveforms. Ratio (Divide) – Calculates the ratio of two wavef
Getting Started Manual 922172-00 Rev A 67 Setting up a Math Trace 1. Press the Math front panel button Or, touch Math Math Setup… from the M
WaveSurfer MXs-B Oscilloscopes 68 922172-00 Rev A 3. Touch any of the icons to select the math operator (function) that you desire. Scroll down thro
Getting Started Manual 922172-00 Rev A 69 Math Descriptor Label When a Math trace is ON, there is a descriptor label on the display for it, much lik
WaveSurfer MXs-B Oscilloscopes 70 922172-00 Rev A Panel Control Zoom Control Action Delay Zooms horizontal position Timebase Zooms horizontal scale
Getting Started Manual 922172-00 Rev A 71 Pass/Fail Testing Overview The WaveSurfer MXs-B oscilloscope’s pass/fail testing is designed for basic det
WaveSurfer MXs-B Oscilloscope iv 922172-00 Rev A Standard outputs ...
WaveSurfer MXs-B Oscilloscopes 72 922172-00 Rev A Setting Up Pass/Fail Testing Touch Analysis Pass/Fail Analysis from the menu bar. The following
Getting Started Manual 922172-00 Rev A 73 Mask Testing Setup 1. From the Test dialog (right side of the screen), choose one of the Test is True whe
WaveSurfer MXs-B Oscilloscopes 74 922172-00 Rev A Saving and Recalling Waveforms Overview There are several ways to save and recall your signals:
Getting Started Manual 922172-00 Rev A 75 Touch the Channel, Math, or Zoom descriptor label twice to open the dialog for the trace that you desire
WaveSurfer MXs-B Oscilloscopes 76 922172-00 Rev A Using Memory Toolbar Shortcuts These toolbar shortcuts can be used to perform specific actions for
Getting Started Manual 922172-00 Rev A 77 4. Choose a data format. If you select ASCII or Excel, also touch the SubFormat field and
WaveSurfer MXs-B Oscilloscopes 78 922172-00 Rev A Recalling Waveform Data 1. Choose File Recall Waveform from the menu bar. 2. Choose to re
Getting Started Manual 922172-00 Rev A 79 Saving the Screen Image to a File Choose File if you want to save the screen image to storage media, such
WaveSurfer MXs-B Oscilloscopes 80 922172-00 Rev A 4. Under Colors, touch the Use Print Colors checkbox if you want the traces printed on a white bac
Getting Started Manual 922172-00 Rev A 81 Saving the Screen Image to a Clipboard Choose Clipboard if you want to save the screen image to the clipb
Getting Started Manual 922172-00 Rev A 1 Welcome Thank you for purchasing a Teledyne LeCroy product. This Operator's Manual includes important
WaveSurfer MXs-B Oscilloscopes 82 922172-00 Rev A Recalling Oscilloscope Settings from a Setup File Choose File Recall Setup from the menu bar.
Getting Started Manual 922172-00 Rev A 83 The WaveSurfer MXs-B oscilloscope uses WindowsXP, so you are probably aware of the basic philosophy of min
WaveSurfer MXs-B Oscilloscopes 84 922172-00 Rev A Documenting Your Work Using LabNotebook The LabNotebook feature simplifies the way waveforms, scre
Getting Started Manual 922172-00 Rev A 85 crucial that the oscilloscope be kept up to date with Windows Critical Updates, and that anti-virus softwa
WaveSurfer MXs-B Oscilloscopes 86 922172-00 Rev A Accessing the Desktop You can access the WaveSurfer MXs-B oscilloscope’s (Windows) desktop by tou
Getting Started Manual 922172-00 Rev A 87 4. Create Label Text by using the pop-up keyboard. You may also change Horizontal Position of each l
WaveSurfer MXs-B Oscilloscopes 88 922172-00 Rev A Printing Since the WaveSurfer MXs-B oscilloscope runs on a WindowsXP platform, you can connect any
Getting Started Manual 922172-00 Rev A 89 Printing from the Oscilloscope 2. You can print in one of three ways: 3. Press the printer button on the
WaveSurfer MXs-B Oscilloscopes 90 922172-00 Rev A Utilities and Preferences Overview The Utilities and Preferences dialogs are accessed from the menu
Getting Started Manual 922172-00 Rev A 91 Remote Communication Setup If you are connecting the oscilloscope to a network, first contact your Informa